| Manufacturer's Description |
The ME453 and ME538 Microwave System Analyzer series are used to measure the transmission line characteristics in the BB and IF bands in terrestrial microwave radio relay systems and in satellite communication systems. The above types of transmission distortion can be measured and analyzed with them.
They have been designed with special emphasis on measurement items, performance, functions, precision and size so that they can be used for all types of microwave radio relay systems, such as FDM-FM relay systems, high efficiency large-capacity digital microwave radio relay systems, and INTELSAT and other satellite communications systems. Unique special innovations contribute greatly to improving handling ease. To improve operational ease, a number of internal controls are used and some measurements are automatic.
Furthermore, the measuring parameters and measured values are displayed digitally, so even when one of these analyzers is used for the first time, results can be obtained quickly and accurately.
The IF and BB frequencies must coincide for remote testing with other models or instruments of other manufacturers. This condition can be met quite easily by selecting the appropriate model from this particular series. |
| Specifications |
IEEE Std 488-1978: IEEE Standard Digital Interface for Programmable Instrumentation.
Bus line consists of 16 signal lines and 8 ground lines.
Data bus (8 lines)
DIO 1 - DIO 8
Data byte transfer control
DAV, NRFD, NDAC
General interface management (5 lines)
ATN, REN, IFC, SRQ, EOI
Click on the Additional Information link above for detailed specifications on this product. |